Model Number : MQ135 MQ-135
Place of Origin : CN
MOQ : 1PCS
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 5000PCS
Delivery Time : 5-8 work days
Packaging Details : Standard packaging
Heater Voltage (VH) : 5.0V±0.1V (AC or DC)
Heater Resistance : 30Ω±3Ω
Heater Consumption : ≤950mW
Output Voltage (Vs) : 2.0V - 4.0V (in 400ppm H₂)
Concentration Slope (α) : ≤0.6 (R₄₀₀ ppm/R₁₀₀ ppm H₂)
Standard Test Conditions : Temperature 20℃±2℃, humidity 55%±5% rh
MQ135 Gas Sensor For Domestic Gas Alarms Portable Gas Detectors
Working Principle:
The sensitive material of the MQ135 gas sensor is SnO₂, which has lower conductivity in clean air. When the target pollution gas exists, the sensor's conductivity increases with the rise of the gas concentration. Users can convert the change of conductivity into the corresponding output signal of the gas concentration through a simple circuit.
Features:
Main Applications:
It is widely used in domestic gas alarms, industrial gas alarms, and portable gas detectors, as well as air quality control equipment for buildings and offices.
Structure Description:
The MQ135 gas - sensitive element is composed of a micro - AL₂O₃ ceramic tube, a SnO₂ sensitive layer, a measuring electrode, and a heater, which are fixed in a cavity made of plastic or stainless steel. The packaged gas - sensitive element has 6 pin - shaped pins, 4 of which are used for signal extraction, and 2 are used for providing heating current.
| Parameter | Symbol | Value | Unit | Remarks | 
|---|---|---|---|---|
| Loop Voltage | Vc | 5.0V ± 0.1V | DC | -- | 
| Heater Voltage | VH | 5.0V ± 0.1V | AC or DC | -- | 
| Load Resistance | RL | Adjustable | Ω | -- | 
| Heater Resistance | RH | 30Ω ± 3Ω | -- | At room temperature | 
| Heater Power Consumption | PH | ≤ 950 | mW | -- | 
| Detection Range | -- | 10 - 1000 | ppm | For ammonia, toluene, hydrogen, smoke, etc. | 
| Sensitivity | S | Rs (in air)/Rs (in 400ppm H₂) ≥ 5 | -- | -- | 
| Output Voltage | Vs | 2.0 - 4.0 | V | In 400ppm H₂ | 
| Concentration Slope | α | ≤ 0.6 | -- | R₄₀₀ ppm/R₁₀₀ ppm H₂ | 
| Operating Temperature | Tao | - 10 - 45 | ℃ | -- | 
| Storage Temperature | Tas | - 20 - 70 | ℃ | -- | 
| Relative Humidity | RH | ≤ 95 | % | -- | 
| Standard Test Temperature | -- | 20℃ ± 2℃ | -- | -- | 
| Standard Test Humidity | -- | 55% ± 5% | -- | -- | 
| Oxygen Content | -- | ≥ 18 | % | 21% is optimal, which will affect the initial value, sensitivity and repeatability of the sensor | 
| Pre - heat Time | -- | ≥ 48 | h | -- | 

|   | 
| MQ135 MQ-135 Gas Sensor For Domestic Gas Alarms Portable Gas Detectors Images | 
 H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                                                        
                                                        
                        
                        
                        
                                                            H2S-AH High Current Hydrogen Sulfide Sensor for Portable Devices 0.03 PPM
                                                    
                        
                     NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                                                    
                        
                        
                        
                                                            NH3-B1 Four Electrode Electrochemical Ammonia Sensor (NH3 sensor) Is Used In
                                                    
                        
                     H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                                                    
                        
                        
                        
                                                            H2S-B4 High Resolution Hydrogen Sulfide Sensor (H2S sensor) Is Used To Monitor
                                                    
                        
                     NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                                                    
                        
                        
                        
                                                            NO2-A1 Nitrogen Dioxide Sensor (Portable NO2 Sensor) For Nitrogen Dioxide
                                                    
                        
                     NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection
                                                                                    
                        
                        
                        
                                                            NO-A1 Nitric Oxide Gas Sensor NO sensor Used For Automobile Exhaust Detection
                                                    
                        
                     NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                                                    
                        
                        
                        
                                                            NH3/CR-50 Ammonia Detection Sensor Highly Sensitive NH3 Measurement 3 Electrode
                                                    
                        
                     SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                                                    
                        
                        
                        
                                                            SR-H-MC ACU01-U00 MICROceL H2S Hydrogen Gas Sensor Three Electrode Electrochemis
                                                    
                        
                     GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                                                    
                        
                        
                        
                                                            GS+4NO2 Nitrogen Dioxide NO2 Gas Sensor 4 Series 3PIN Use In Industry
                                                    
                        
                     SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                                                    
                        
                        
                        
                                                            SR-W-MP75C Micropel 75C Combustion Gas Sensor Catalytic Oxidation
                                                    
                        
                     TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen
                                                                                        
                                                        
                        
                        
                        
                                                            TGS826 NH3 Ammonia Gas Detector Sensor Low Conductivity Resistance To Environmen