Brand Name : YJJ
Place of Origin : CHINA
MOQ : 1
Price : Negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 1500
Delivery Time : 5 to 8 working days
Packaging Details : Canned
Model Number : CNLH AA015-000
Measurement Range : 0-2 ppm O2
Maximum Overload : 1000 ppm O2
Filter : None
Output Signal : 13 - 17 mV in air with a 10Ω
Response Time (T95) : < 20 seconds
Purge Time : < 6 hours
Product Description:
YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes
Features:
CITIPEL Sensor product introduction
 The service life of the C/NLL Oxygen CiTiceL is inversely proportional to the amount of oxygen consumed by the sensor. Because City Technology does not have knowledge of the operating conditions of any particular application, the company cannot provide any guarantees about the service life of the sensors. However, the following guidelines should be used:
 Under normal operating conditions (i.e. ppm level), the sensor has a large excess capacity and will only gradually lose sensitivity. However, it is recommended to replace the sensor annually to maintain the best sensitivity.
 It is recommended not to use these sensors in ambient air, or to keep them in the air for long periods of time. This will greatly reduce the service life of the sensor.
2-electrode electrochemical
 0-2 ppm O,
 1000 ppm O.
 Operating Principle
 Measurement Range
 Maximum Overload
 Filter
 Qutput Signa!
 None
 13 _17 mV in air with a 100
 load resistor
 < 20 seconds
 < 6 hours
 Response Time (T.)
 Purge Time:
 (Ambient air to <10 ppm)
 Linearity Linear
 ELECTRICAL
 Recommended Load Resistor 10 Ω
 MECHANICAL
 Weight |32 g
 Housing Material:
 Nickel plated steel
 Body
 Current Collectors Nickel
 Orientation Sensitivity None
 ENVIRONMENTAL
 Operating Temperature Range -20'C to +50°C
 Temperature Coefficient
 0.2% signal/°C
 Recommended Storage Temp
 0'C to 20°C
 Atmospheric±10%
 Operating Pressure Range
 Operating Humidity Range
 0-99% RH non-condensing
 LIFETIME
 Long Term Output Drift
 Expected Operating Life
 Storage Life
 <5% signal losslyear
 See below
 6 months in CTL container
Specifications:
| Orientation Sensitivity | None | 
| Current Collectors | Nickel | 
| Body | Nickel plated steel | 
| Weight | 32 g | 

| 
                                             | 
                
                        YJJ C/NLH CNLH Trace Oxygen Sensor 0-1000 PPM AA015-000 Is Used For Trace Oxygen Detection In Glove Boxes Images |